sane\-umax_pp
Section: SANE Scanner Access Now Easy (5)
Updated: 14 Jul 2008
Index
Return to Main Contents
NAME
sane-umax_pp - SANE backend for Umax Astra parallel port flatbed scanners
DESCRIPTION
The
sane-umax_pp
library implements a SANE (Scanner Access Now Easy) backend that
provides access to Umax parallel port flatbed scanners. The
following scanners work with this backend:
-
Model:
--------------------
Astra 610P
Astra 1220P
HP3200C
Astra 1600P
Astra 2000P
Genius ColorPage-Life Pro
This backend handles 75x75, 150x150, 300x300, 600x600 and 600x1200 for 1220P/1600P/2000P
dpi scan reslutions,and 75x75, 150x150, 300x300 and 300x600 for 610P. In color and gray
levels, there is a software lineart mode.
The new generation models share a newer version of the 610P ASIC embedded in an EPAT chip.
Only parts such as CCD and ADC change from
one to another. They even all reports being UMAX Astra 1220P via IEEE1284.
There isn't software way to recognize them properly. Under windows, model is
set by the driver installed, regardless of the hardware.
- EPP/ECP MODES ONLY
-
The current version of the backend uses only EPP or ECP mode to communicate
with the scanner. PS/2 mode isn't implemented. The 610P only use SPP. It is
recommended that you set your parallel port to EPP in BIOS with the current
version of this
backend. You can leave it to ECP or ECP+EPP, but in this case you may not use
ppdev but only direct hardware access if you have to use ECP. ECPEPP will only
work if you use a 2.4 or 2.6 kernel with ppdev character device support.
This backend does support parport sharing only
if you have a kernel with ppdev support.
Note that if you don't use the ppdev character device, the backend
needs to run as root. To allow user access to the scanner
run the backend through the network interface (See saned(8) and sane-net(5)).
A more relaxed solution (security wise) is to add suid bit to the frontend
(See chmod(1)).
The backend drop root priviledges as soon as it can, right after gaining direct
access to IO ports, which lessen risks when being root.
DEVICE NAMES
This backend expects device names of the form:
-
port value
Where
value is :
-
- auto
-
autodetect all parallel ports and probe
them for scanner
- safe-auto
-
autodetect all parallel ports and probe
them for scanner, but does not try direct
hardware access
- /dev/ppi0
-
uses *BSD ppi device, depending on the
number of available parallel port, you
have to use /dev/ppi1, /dev/ppi2, ...
- /dev/parport0
-
uses linux ppdev device, depending on the
number of available parallel port, you
have to use /dev/parport1, /dev/parport2, ...
- 0x378
-
does direct hardware access on the given
address. Usual values are 0x378, 0x278, 0x3BC
In this case, you have to run the scanner as
root (*BSD and linux), or with 'IOPL=yes' on
OS/2
NOTE: in all cases, you must have sufficient priviledges
to get access to the chosen device or address. Depending on the
security settings, devices may not be available for all users.
You have to change permissions on the dev/ppi* or /dev/parport* devices.
You can rename any device using the
-
name devname
model model
vendor vendor
options. These options apply to the last port option.
CONFIGURATION
Please make sure to edit umax_pp.conf
before
you use the backend.
The contents of the
umax_pp.conf
file is a list of options and device names that correspond to Umax
scanners. Empty lines and lines starting with a hash mark (#) are
ignored.
The eight options supported are
red-gain,
green-gain,
blue-gain,
red-offset,
green-offset,
blue-offset,
astra,
and
buffer.
Options
red-gain
,
green-gain
and
blue-gain
allow you to adjust the sensitivy of your scanner for the given color. Values
range from 0 (lowest gain) to 15 (highest). If the advanced option "Gain" isn't
checked in the frontend, the backend does automatic gain calibration, and do not use
user provided values.
Options
red-offset
,
green-offset
and
blue-offset
allow you to adjust the offset of your scanner for the given color. Values
range from 0 (lowest offset) to 15 (highest).
Option
astra
allows you to change the model of your scanner. Current auto detection is based
on side effects on scanning when using 1220P command set on other models, so
it may fail on unkown hardware combination. Valid values are 610, 1220, 1600
and 2000. It is usefull only when autodetection fails to detect properly
your scanner model. If your scanner work properly but is reported wrongly,
let it be that way.
The only valid case to change the model is when your scanner produces "black" or
"inverted" scans. In this case you can put the model. Be aware that it will
prevent scanner model autodetection.
Option
buffer
allows you to change the size of the scan buffer. The size must be specified in
bytes. The default value is 2 megabytes. Decreasing this value will improve the
smoothness of progress bar in the frontend, but will stall the
scan more often.
FILES
- /etc/sane.d/umax_pp.conf
-
The backend configuration file (see also description of
SANE_CONFIG_DIR
below).
- /usr/lib/sane/libsane-umax_pp.a
-
The static library implementing this backend.
- /usr/lib/sane/libsane-umax_pp.so
-
The shared library implementing this backend (present on systems that
support dynamic loading).
ENVIRONMENT
- SANE_CONFIG_DIR
-
This environment variable specifies the list of directories that may
contain the configuration file. Under UNIX, the directories are
separated by a colon (`:'), under OS/2, they are separated by a
semi-colon (`;'). If this variable is not set, the configuration file
is searched in two default directories: first, the current working
directory (".") and then in /etc/sane.d. If the value of the
environment variable ends with the directory separator character, then
the default directories are searched after the explicitly specified
directories. For example, setting
SANE_CONFIG_DIR
to "/tmp/config:" would result in directories "tmp/config", ".", and
"/etc/sane.d" being searched (in this order).
- SANE_DEBUG_UMAX_PP
-
If the library was compiled with debug support enabled, this
environment variable controls the debug level for this backend. E.g.,
a value of 128 requests all debug output to be printed. Smaller
levels reduce verbosity.
-
level debug output
------- ------------------------------
0 nothing
1 errors
2 warnings & minor errors
3 additional information
4 debug information
5 code flow (not supported yet)
6 special debug information
- SANE_DEBUG_UMAX_PP_LOW
-
This variable sets the debug level for the SANE interface for the Umax
ASIC. Note that enabling this will spam your terminal with some
million lines of debug output.
-
level debug output
------- -------------------------------
0 nothing
1 errors
8 command blocks
16 detailed code flow
32 dump datafiles
255 everything
SEE ALSO
sane(7), sane-net(5), saned(8)
- For latest bug fixes and information see
-
http://umax1220p.sourceforge.net/
AUTHOR
St['e]phane VOLTZ <stef.dev@free.fr>
CREDITS
Support for the 610P has been made possible thank to an hardware donation
by William Stuart.
BUG REPORTS
If something doesn't work, please contact me. But I need some information about
your scanner to be able to help you...
- SANE version
-
run "scanimage -V" to determine this
- the backend version and your scanner hardware
-
run "SANE_DEBUG_UMAX_PP=255 scanimage -L 2>log" as root. If you don't get any output
from the umax_pp backend, make sure a line "umax_pp" is included into
your /etc/sane.d/dll.conf.
If your scanner isn't detected, make sure you've defined the right port address, or the
correct device
in your umax_pp.conf.
- the name of your scanner/vendor
-
also a worthy information. Please also include the optical resolution and lamp type of your scanner, both can be found in the manual of your scanner.
- any further comments
-
if you have comments about the documentation (what could be done better), or you
think I should know something, please include it.